Panel prefilters
Capture coarse dust at the first filtration stage and protect downstream filters.
G3 / G4 · EN 779
View specifications →Welcome to PARSWOOD™
Explore PARSWOOD™ air filters for building ventilation, industrial air handling and controlled environments. Choose a filter family or send us your existing filter details for selection support.
Start with the filter format you already use, or browse by application. Each family has its own construction options and technical requirements.

Capture coarse dust at the first filtration stage and protect downstream filters.
G3 / G4 · EN 779
View specifications →
A pocket-format first stage for coarse particle loading in ventilation systems.
G4 · EN 779
View specifications →
A larger media area for intermediate filtration in building and industrial air systems.
M5, M6, F7, F8, F9 · EN 779
View specifications →
A compact arrangement of multiple media banks for higher airflow duties.
Medium-efficiency and HEPA configurations; exact grade to be confirmed
View specifications →
Compact high-efficiency filtration for cleanroom equipment and controlled air supplies.
H13 / H14 / U15 · EN 1822 at MPPS
View specifications →
Gel-seal configurations for housings designed around a matching knife-edge interface.
H13 / H14 / U15 · EN 1822 at MPPS
View specifications →
Deep-pleat media with separators, offered in distinct medium-efficiency and high-efficiency configurations.
F7 / F8 / F9 · EN 779; E12 / H13 / H14 · EN 1822
View specifications →
Temperature-specific separator filters for heated-air equipment.
H13 configuration; other grade combinations require confirmation
View specifications →Ask about activated carbon filters and fan filter units. For gas-phase selection, include the target contaminant, concentration, temperature and humidity. For an FFU, include airflow, power supply, controls and the required filter class.
Discuss a specialist requirement →| Family | Classification options | Media | Temperature* |
|---|---|---|---|
| Panel prefilters | G3 / G4 · EN 779 | Polyester synthetic fibre | 80°C / 176°F |
| Primary pocket filters | G4 · EN 779 | Polyester synthetic fibre | 80°C / 176°F |
| Medium-efficiency pocket filters | M5, M6, F7, F8, F9 · EN 779 | Synthetic fibre | 80°C / 176°F |
| V-bank filters | Medium-efficiency and HEPA configurations; exact grade to be confirmed | Microglass fibre | 80°C / 176°F |
| Mini-pleat HEPA & ULPA filters | H13 / H14 / U15 · EN 1822 at MPPS | Moisture-resistant microglass fibre | 80°C / 176°F |
| Gel-seal HEPA & ULPA filters | H13 / H14 / U15 · EN 1822 at MPPS | Moisture-resistant microglass fibre | 80°C / 176°F |
| Separator filters | F7 / F8 / F9 · EN 779; E12 / H13 / H14 · EN 1822 | Microglass fibre | 80°C / 176°F |
| High-temperature filters | H13 configuration; other grade combinations require confirmation | High-temperature microglass fibre | 150 / 280 / 350°C configurations |
*Configuration-dependent limits. EN 779 grades are legacy classifications shown in the supplied technical information; they are not automatic equivalents to ISO 16890 or MERV ratings. Ask for evidence against the standard in your project specification.
Send actual dimensions, the existing label and your application. Include the seal and frame details.
Review efficiency, airflow and initial pressure drop together. Confirm available fan capacity and operating conditions.
Agree the configuration, supporting documents, quantity and delivery requirement before ordering.
Explore healthcare, facilities and general-industry applications →
You do not need every specification to start. A clear label photo and actual dimensions are often the best first step.
Width × height × depth, quantity, existing grade and where the filter is installed. Add airflow, pressure drop or temperature if your application specifies them.
Submit your requirements directly to our team. If you have photographs or drawings, mention them in your enquiry and we can follow up by email.
Check actual dimensions, frame and seal details first. Nominal labels can differ from the physical size, and a matching width and height do not confirm performance.
Efficiency must be considered with airflow, resistance and the system design. Review the proposed filter at the required duty point before changing grades.
A filter grade describes tested filter performance. The housing, installation seal, airflow and any required installed testing also need to satisfy the project requirements.
Include that request with your enquiry. PARSWOOD™ can review available documentation for the proposed configuration, rather than applying one curve to an entire family.